Main Page | About Us | E-Mail Access | Contact
  MAIN RESEARCH
DIRECTIONS
  PARTICIPATION AT
EUROPEAN PROJECTS
  PARTICIPATION AT
NATIONAL PROJECTS
  LABORATORIES FOR
EXPERIMENTING, TESTING
AND EXAMINATION
  MICRO PRODUCTION,
SERVICES, PARTNERSHIPS
  RESEARCH & DEVELOPMENT
ACTIVITY ACKNOWLEDGEMENT
  MANAGEMENT SYSTEM
OF QUALITY
  PRODUCTS AND SERVICES







  Ads
 

COMOTI Institute has GHH-RAND license for production and service of screw compressors. Contact

 
1.3.1.2 Centrifugal compressor for natural gas

ELECTRICAL CENTRIFUGAL GAS COMPRESSOR
ECG – 7 – 250

USAGE AREAS

· compression of natural gas within natural gas extraction units;
· compression of crude-oil installation gas within crude-oil production units;
· gas pressure rising set for high and low pressure ducts within TRANSGAZ DISTRIGAZ


WORKING PARAMETERS

· compressed gas: natural gas (relative density around 0,61);
· aspiration pressure denominated / maximum: 1,5 bars / 1,8 bars;
· heading pressure: 7,5 bars;
· aspiration temperature: 15 0C;
· heading temperature: 40 – 50 0C (with cooling);
· headed flow denominated / maximum : 275.000 Nm3/day / 375.000 Nm3/day;
· carrying away : electric motor asynchronous with the rotor in by-pass 1200 kW, 6kV, 50 Hz, MIB Exd II BT4, 1500 rot/min;
· specific electrical energy consumption: maximum 72 kW/1000 Nm3;
· external sizes (Lxlxh): 5500x2500x2350 mm;
· total weight : 27.000 daN.


PRODUCT COMPONENT

· centrifugal compressors set and multiplication device;
· electric drive motor;
· coupling between the electric motor-multiplication device;
· bed set ;
· command system, adjustment, control (with micro chip);
· tightening and oiling system /dam;
· anti-explosive installation.


LAYOUT

· covered space, bridge-crane at least 10 tf, lowest temperature 5 0 C ;
· foundation: size about 5500x2200x2000 mm insulated.

UTILITIES


· high voltage power line 6 kV , with automated starting transformer;
· low voltage power line 380 V – consumption minimum/maximum 1,5/16,5 kW;
· water cooling circuit:
o cooling tower with an Dt minimum : 8 0 C;
o cooling water flow : 90 m3/h;
o maximum of water temperature entering in cooler : 30 0 C;
o cooling water pressure : 3,5 bar.
· air for driving anti-pumping valve :
o class II conform STAS 8842;
o working pressure 4 ÷ 6 bars .
· gas for driving air motor, auxiliary pump for oiling the valve :
o clean, dry gas;
o pressure 6 ÷ 8 bars.

FUNCTIONING RESOURCES

· between over-hauling: 32.000 hours;
· total resource: 4 over-hauling.

WARRANTIES

· 8000 functioning hours, but no more than 18 months from delivery ;
· spare parts, available to buy, at least 15 years from delivery ;
· post warranty service available on contract

REFFERRAL

- the ECG-7-250 set has been validated in in April 1999, in the S.P.Ţicleni unit– of PETROM Group, totaling 12,000 functioning hours, with an usage percentage of 92%.
Main Page | About Us | E-Mail Access | Contact
Web design : Dezibel Media | Hosting and maintenance: INCDTurboengines COMOTI National Research & Development Institute for Gas Turbines INCDT COMOTI, COMOTI, Research, Development, Innovation, Gas Turbines, compressors, laboratory, mobile laboratory, mobile station, acoustics, vibrations, vibration analysis, acoustic analysis, FFT analysis, FFT, COMOTI, comoti.ro, www.comoti.ro, laboratory of acoustics, vibration laboratory, laboratory of acoustics and vibrations, noise diagnosis, noise, noise analysis, spectra, spectrum, cepstru analysis, diagnosis, diagnosis acoustics, vibration diagnosis, diagnosis sounds, noise diagnosis, monitoring, acoustic monitoring, vibration monitoring, noise monitoring, noise maps, acoustic mapping, noise mapping, making acoustic maps, acoustic, acoustic measurements, vibration measurement, noise measurement, acoustic projects, projects vibrations, noise projects, research, acoustics, vibrations research, sound research, research and development, development acoustics, acoustic protection, Natural Gas Screw Compressors, CU Series under IR licence